logo
Inicio Productosmembrana de la ultrafiltración

SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment

Certificación
China Sinomemb Environment Technology (beijing) Co., certificaciones
China Sinomemb Environment Technology (beijing) Co., certificaciones
Estoy en línea para chatear ahora

SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment

SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment
SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment

Ampliación de imagen :  SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment

Datos del producto:
Lugar de origen: PORCELANA
Nombre de la marca: SINOMEMB
Número de modelo: SNU-HO-2-T865
Pago y Envío Términos:
Cantidad de orden mínima: 5
Detalles de empaquetado: Embalaje de exportación estándar

SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment

descripción
Especificaciones: 4 Altura: 1560 mm
Caudal: 1-1000 L/H Rango de pH tolerable: 1 a 13
Material de membrana: PVC/PVDF/PS/PES Filtrar: Membrana de la ósmosis reversa
Modo de filtración: Flujo cruzado Componentes centrales: UF Acero
Alojamiento: UPVC Solicitud: Concentración de pintura electroforética

n SINOMEMB ® UF membrane module SNU-HO-2-T865 type

The core SINOMEMB ® series SN U-HO- 2 -T865 hollow fiber UF membrane element is suitable for systems with a capacity of more than 50 m 3 /hr (220gpm) . The compact design helps customers to achieve a more economical membrane system design . It has stable chemical properties, strong resistance to cleaning agents , high reliability, and easy maintenance . It is widely used in surface water, well water, seawater , industrial wastewater and sewage Various water treatment applications such as secondary and tertiary treatment .

Ø Membrane element specifications

Membrane element model

Effective membrane area

ft 2 (m 2 )

Effective volume

G( L )

weight empty /full of water

( kg )

SN U-HO-2- T 865 700(65) 10(38) 50/85
Inlet size Water outlet size Concentrated water outlet size Membrane Polymer
DN50 DN50 DN50 PVDF
Membrane inner diameter/outer diameter (mm) Filtration precision (μ m ) shell material Sealant material
0.7/1.3 0.03 U-PVC epoxy resin

Ø Membrane element operating parameters

Filtration flux ( 25℃ ) L/㎡·hr 40-90
Flow range ( 25℃ ) m³/hr 2.6-5.85
Maximum influent turbidity (NTU) ≤100
Maximum resistance to residual chlorine (NaCLO) (ppm) Continuous: 200; Momentary: 5000
Maximum anti-suspended solid capacity (ppm) ≤100
Maximum influent COD (ppm) 100
Working temperature (℃) 15-40
pH range 2-12
Maximum water production (L/m³·h) 150
Maximum water inlet pressure ( 20°C ) (Mpa) 0.3
Maximum transmembrane pressure difference (Mpa) 0.2
Maximum backwash pressure (Mpa) 0.25
Maximum air flushing flow rate (Nm³/hr) 10-18
General backwash cycle (min) 15-60
General backwash time (sec) 30-60
General backwash flow rate (L/m³·h) 150-270
General chemical enhanced backwash cycle (day) 1-15
General chemical backwashing time (min) 1-15
General chemical cleaning cycle (day) 30-180
General chemical cleaning time (min) 90-480
General chemical cleaning chemicals NaClO or H2O2 20 00ppm , NaOH (PH≤10), HCl ( PH≥2 )
How to run /operate outside-in / full flow or cross flow filtration
Expected water production SDI ≤3
Expected product water turbidity NTU ≤0.1
Bacteria removal rate (log) >4
E. coli removal rate (log) >6
service life ≥3 years under standard conditions

Ø Membrane element size

SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment 0SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment 1SINOMEMB reg UF Membrane Element SN U-HO-2-T865 Ideal for Surface Water Well Water and Industrial Wastewater Treatment 2

L L1 L2 L3 L4 Diameter Φ air intake
1985mm 1500mm 1755mm 1945mm 180mm 225mm RP 3/8”
(78.1)in (59.1)in (69.1)in (76.6)in (7.1)in (8.9)in /

Ø Membrane element operation guide

During the operation of the UF system, it is necessary to avoid sudden changes in pressure during system start-up, shutdown, operation, cleaning, maintenance, etc., as well as exceeding the maximum withstand pressure specified in this manual, to prevent possible membrane breakage, sealing, etc. End fall off, membrane shell cracking and other serious damage consequences; this series of products have been treated with anti-corrosion and membrane wire protection before leaving the factory, and the inner membrane wire of the module is in a semi-dry state. For manual operation, the water production rate should be set to 50% of the design water production rate, and the initial water production must be discharged directly and cannot be used as product water.

Ø Membrane element product usage tips

The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.

Ø Disclaimer

Failure to operate in strict accordance with the operating limits and guidelines set forth herein voids our limited warranty. If the UF system is out of service, please inject protective liquid inside the membrane module for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.